DPDQ402000 - Carel Duct mounting CO2 sensor with a 0 to 10 Vdc output

£1,781.99 £1,484.99 Price match guarantee
On request
SKU
DPDQ402000
Next Supplier Stock Update: 11/03/2025
Manuals & Datasheets
 DATA-SHEET 
DATASHEET
 
Product typeSensors & Stats
IP ratingIP65
Output Signal0..10Vdc
ManufacturerCarel
Sensor TypeAir Quality
Sensor characteristicsDuct Mounted
DPDQ402000 - Duct mounting CO2 sensor with a 0 to 10 Vdc output Carel Duct mounting CO2 Air quality sensor with a 0..10V output

Datasheet

APPLICATION:

The self-calibrating microprocessor-controlled CO2 and mixed gas measuring device is used for the detection of air quality and ⁄ or CO2 content in air within a range of 0 ppm to 2000 ppm CO2. Measuring signals are converted into standard signals of 0 -10V. The CO2 content of air is determined by a NDIR sensor. Self-calibration of the CO2 measurement takes place in cycles of ca. 7 days. In order to ensure this function, it is necessary to provide the device with fresh air (CO2 content 300 ... 400 ppm) at least once every 7 days. The air quality detection range is calibrated for standard applications such as monitoring in residential and conference rooms. The lifetime of the mixed gas sensor used for this purpose is limited. It depends on type and concentration of pollutant gases. When device-specific parameters are observed, the expected lifetime is at least 36 months.

TECHNICAL DATA:

Power supply: .................................. 24 V AC ⁄ DC

CARBON DIOXIDE :

Sensor, CO2: .................................... optical sensor (NDIR)

Measuring range, CO2: .................. 0 … 2.000 ppm CO2

Output, CO2: .................................... 0 - 10 V

Measuring accuracy, CO2: ............ ± 30 ppm, ± 5 % of final value

Pressure dependence: .................. ± 1.6 % ⁄ kPa (referred to normal pressure)

Long-term stability: ........................ ± 1 % of final value per year

Gas exchange: ................................. by diffusion

TECHNICAL FEATURES - ACTIVE AIR QUALITY SENSORS DUCT VERSION

 

 

DPDQ306000 (VOC)

 

Sensor:

VOC sensor (metal oxide)

Measuring range:

0…100% air quality; referred to calibrating gas

Output signal:

0-10 V (0 V=clean air, 10 V=polluted air) o 4…20 mA (selectable via jumper)

Measuring accurancy:

± 20% of final value (referred to calibrating gas)

Long-term stability:

<10% / per year

Sensor protection:

sinter filter, exchangeable, screwed, easy to clean

DPDQ402000 (CO2)

 

Sensor CO2:

optical sensor

Measuring CO2:

0…2000 ppm CO2

Output CO2:

0-10 v

Measuring accurancy CO2:

± 30 ppm, ± 5% of final value

Long-term stability:

+ 1% of final value per year

 

 

DPDQ502000 (VOC+CO2)

 

Air quality sensor:

VOC sensor (metal oxide)

Measuring range, air quality

0…100% (mixed gas pollution referred to calibrating gas)

Output air quality:

0-10 V (0 V=clean air, 10 V=polluted air)

Measuring accuracy, air quality:

± 20% of final value (referrred to calibrating gas)

 

 

Common features

 

Power supply:

24 Vac/15-36 Vdc

Ambient temperature:

0…+50 °C

Electrical connection:

0.14 – 1.5 mm2 via screw terminals on circuit board

Warm-up period:

1 hour

Installation:

by mounting flange, plastic and galvanised steel optional

Protection type: