Product type | Sensors & Stats |
IP rating | IP65 |
Output Signal | 0..10Vdc |
Manufacturer | Carel |
Sensor Type | Air Quality |
Sensor characteristics | Duct Mounted |
APPLICATION:
The self-calibrating microprocessor-controlled CO2 and mixed gas measuring device is used for the detection of air quality and ⁄ or CO2 content in air within a range of 0 ppm to 2000 ppm CO2. Measuring signals are converted into standard signals of 0 -10V. The CO2 content of air is determined by a NDIR sensor. Self-calibration of the CO2 measurement takes place in cycles of ca. 7 days. In order to ensure this function, it is necessary to provide the device with fresh air (CO2 content 300 ... 400 ppm) at least once every 7 days. The air quality detection range is calibrated for standard applications such as monitoring in residential and conference rooms. The lifetime of the mixed gas sensor used for this purpose is limited. It depends on type and concentration of pollutant gases. When device-specific parameters are observed, the expected lifetime is at least 36 months.
TECHNICAL DATA:
Power supply: .................................. 24 V AC ⁄ DC
CARBON DIOXIDE :
Sensor, CO2: .................................... optical sensor (NDIR)
Measuring range, CO2: .................. 0 … 2.000 ppm CO2
Output, CO2: .................................... 0 - 10 V
Measuring accuracy, CO2: ............ ± 30 ppm, ± 5 % of final value
Pressure dependence: .................. ± 1.6 % ⁄ kPa (referred to normal pressure)
Long-term stability: ........................ ± 1 % of final value per year
Gas exchange: ................................. by diffusion
TECHNICAL FEATURES - ACTIVE AIR QUALITY SENSORS DUCT VERSION |
|
|
|
DPDQ306000 (VOC) |
|
Sensor: |
VOC sensor
(metal oxide) |
Measuring range: |
0…100%
air quality; referred to calibrating gas |
Output signal: |
0-10 V (0
V=clean air, 10 V=polluted air) o 4…20 mA
(selectable via jumper) |
Measuring accurancy: |
±
20% of final value (referred to calibrating gas) |
Long-term stability: |
<10% /
per year |
Sensor protection: |
sinter
filter, exchangeable, screwed, easy to clean |
DPDQ402000 (CO2) |
|
Sensor CO2: |
optical
sensor |
Measuring CO2: |
0…2000
ppm CO2 |
Output CO2: |
0-10 v |
Measuring accurancy CO2: |
± 30
ppm, ± 5% of final value |
Long-term stability: |
+ 1% of
final value per year |
|
|
DPDQ502000 (VOC+CO2) |
|
Air quality sensor: |
VOC sensor
(metal oxide) |
Measuring range, air quality |
0…100%
(mixed gas pollution referred to calibrating gas) |
Output air quality: |
0-10 V (0
V=clean air, 10 V=polluted air) |
Measuring accuracy, air quality: |
±
20% of final value (referrred to calibrating gas) |
|
|
Common features |
|
Power supply: |
24
Vac/15-36 Vdc |
Ambient temperature: |
0…+50
°C |
Electrical connection: |
0.14
– 1.5 mm2 via screw terminals on circuit board |
Warm-up period: |
1 hour |
Installation: |
by mounting
flange, plastic and galvanised steel optional |
Protection type: |
IP65
(according to IEC 529) |